The mFi® output and the switch/dimmer have contact panel for easy operation. The product can be easily placed in any interior.
Built-in mechanical relays enable remote power supply - this allows you to control energy consumption. The mFi® switch/dimmer has a power level adjustment function - set by the dimmer.
Take advantage of the power metering capabilities to easily monitor the energy consumption of the connected devices - and significantly reduce its cost.
The output and mFi® switch/dimmer can be easily connected to any Wi-Fi network.
Intelligent and efficient lighting - thanks to an intuitive user interface and advanced features of the mFi® controller software.
Features / filters | |
AC input frequency | 50 - 60 |
Current | 15 |
Depth | 67.7 |
Depth (imperial) | 6.78 |
Height | 71 |
Height (imperial) | 7.11 |
Operating relative humidity (H-H) | 10 - 95 |
Operating temperature (T-T) | 0 - 40 |
Product colour | Black |
Safety | UL Listed |
Storage temperature (T-T) | -40 - 85 |
Voltage | 110 - 125 |
Weight | 160 |
Width | 110.8 |
Width (imperial) | 11 |
Basic technical parameters | |
Dimensions | 110,8 × 71 × 67,7 mm |
Weight (without wall plate) | 160 g |
Rated values | 110 - 125VAC, 50 - 60 Hz, 15A |
Maximum load | 15A per socket (not simultaneous) 15A total |
Cables | linear, neutral and earthed |
Interface | Status LED Reset button Start button |
LED | Yellow/blue |
Wi-Fi | 802.11b/g/n |
Functions | Dual relays for power control Energy monitoring |
ESD/EMP protection | 8KV air, contact ± 4KV |
Operating temperature | 0 to 40°C |
Working humidity | 10 to 95% |
Shocks and vibrations | -40°C, 2 hours / +85°C, 2 hours, 5 cycles |
Security | UL |
Turn off the power on the circuit breaker or fuse panel.
Check that the power supply is off.
Identify and mark the cabling in the wall box. They should be
two wires and one grounding wire:
- voltage line
- neutral
- Grounding
3. Prepare the cabling in the wall box.
12 mm insulation from the end of each cable.
4 Connect the mFi output wires to the wall box wires and
Secure each connection with a nut
a. Connect the black wire of the mFi output to a line with voltage.
b. Connect the white wire of the mFi output to the neutral connector.
c. Connect the green wire of the mFi output to the ground.
5. bend and shape the wires so that they fit into the wall box. Make sure that
the cables are properly spaced to provide sufficient space for the mFi.
output.
Place the mFi socket inside the wall box and make sure it is mounted flush with the wall. Secure the mFi output with two screws.
7. install a wall plate. Align the mounting brackets with
mounting holes. Press the wall plate until the mounting clips snap into place.
Switch on the power supply at the circuit breaker or in the fuse panel.