EN
PowerBOX is an external router with five Ethernet ports and PoE output for four ports. You can use this device to power four PoE-enabled devices, such as the SXT series.
Since the device has a waterproof outer casing, it can be mounted on a tower or in other outdoor locations. The device has five shielded Ethernet ports, four of which can power other PoE-enabled devices with the same voltage as the device (maximum output current is 1A per port, maximum output current is 2A). Less power supplies and cables to worry about!
Features / filters | |
Number of LAN ports | 5x 10/100BaseTX (RJ45) |
AC adapter included | Yes |
Cabling technology | 10/100Base-T(X) |
CPU frequency | 400MHz |
DC-in jack | Yes |
Depth | 178 |
Ethernet interface type | Fast Ethernet |
Ethernet LAN | Yes |
Ethernet LAN (RJ-45) ports | 5 |
Ethernet WAN | Yes |
Flash memory | 16 |
Height | 48 |
Internal memory | 64 |
Management | By web browser, CLI - Command Line Interface, |
Operating temperature (T-T) | -35 - 70 |
PoE input | Yes |
PoE output | Yes |
Power consumption (typical) | 2 |
Power over Ethernet (PoE) | Yes |
Product colour | White |
RAM memory | 64MB |
Type of case | Plastic |
Type of device power supply | Passive PoE, Power supply, |
Width | 125 |
Basic technical parameters | |
Nominal processor frequency | 400 MHz |
Number of processor cores | 1 |
Size of RAM | 64 MB |
10/100 Ethernet ports | 5 |
10/100/1000 Ethernet ports | There is no |
MiniPCI sockets | 0 |
MiniPCI-e sockets | 0 |
Number of USB ports | 0 |
Socket | 1 |
PoE input | Yes |
Supported input voltage | 5 V - 30 V |
Output PoE | Yes |
Voltage monitor | Yes |
PCB temperature monitor | Yes |
Processor temperature monitor | No |
Dimensions | 125×178×48 mm |
Operating system | RouterOS |
Operating temperature range | -35C +70C |
Licence level | 4 |
Current monitor | Yes |
CPU | AR7241-AH1A-R |
Maximum power consumption | 3W |
Ports SFP | There is no |
Ports SFP+ | There is no |
Serial port | There is no |
Firewall, Routing, MPLS, VPN, Wireless, DHCP, Hotspot, QoS, Proxy and more.
Yes, you can use all the queuing management functions. Set the queue to the outgoing interface as you go through the router. This is not a bridge interface! The queue on the bridge interface is only involved for traffic generated by the router.
When you install RouterOS software or turn on the router for the first time, there are different ways to connect to it:
- Access to command line interface (CLI) via Telnet, SSH, serial cable
- Access to the graphic interface (WebFig)
- Using the WinBox configuration tool (Windows application)
Each router is configured at the factory with IP address 192.168.88.1/24 on Ethernet port1. The default user name is admin without password. After logging in for the first time, please create a new user with the password in group "full". , log in again and delete the default administrator user.