Orvaldi LT-2000 Sinus Tower | UPS | 2000VA/1400W, 4x 7Ah
CODE: VOTLT2K / EAN: 5904006036801
EN
ORVALDI LT sinus tower UPS provides stable operation of sensitive server-class equipment and full protection against power failure, spikes and voltage instability. This unit is dedicated to networking, telecommunications, server equipment and critical computer stations.
Features / filters | |
UPS power (VA) | 2000 |
Audible alarm(s) | Yes |
Battery capacity | 7 |
Battery voltage | 48 |
Depth | 455 |
Emergency Power Off (EPO) | Yes |
Form factor | Mini Tower |
Height | 220 |
Input frequency | 50/60 |
Input operation voltage (max) | 290 |
Input operation voltage (min) | 162 |
Number of batteries supported | 4 |
Output power | 1400 |
Output power capacity | 2 |
Product colour | Black |
Surge protection | Yes |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Width | 145 |
Apparent power/active power | 2000 VA / 1400 W |
Input | |
Permissible voltage range | 162-268 VAC / 162-268 VAC / 170-280 VAC / 177-290 VAC |
Frequency range | 60/50 Hz ± 5 Hz (auto detection) |
Output | |
Voltage regulation (AC mode) | 208 (-10%/ 16%) / 220 (-15%/ 10%) / 230 (-15%/ 10%) / 240 (-15%/ 10%) VAC |
Voltage regulation (bat. mode) | 208/220/230/240 VAC ± 1.5% (before battery alarm) |
Frequency range (bat. mode) | 50 Hz or 60 Hz ± 0.1 Hz |
Transfer time | Typically 2-6 ms, max. 10 ms |
Voltage shape (bat.) | Pure sine wave |
Performance | |
AC Mode | 96% |
Buck mode | 95% |
Battery mode | Up to 90% at nominal battery voltage |
Battery | |
Type and number of batteries | 12 V / 7 Ah x4 |
Charging time | 4 hours charging to 90% capacity |
Security | |
Full protection | Protection against overload, short circuit, discharge and overcharge |
Alarm | |
Battery mode | Alarm signal every 10 seconds |
Low charge | Alarm signal every 2 seconds |
Overload | Alarm signal every second |
Battery replacement | Alarm signal every 2 seconds |
Error | Continuous alarm signal |
Physical | |
Dimensions (length, width, height) [mm] | 455 x 145 x 220 |
Net weight (kg) | 18.1 |
Noise level | Less than 45 dB |
Management | |
Smart RS-232/USB | Supports WIndows 2000/2003/XP/Vista/2008, 7/8/10, Linux, Unix and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
ORVALDI LT-2000 SINUS TOWER are used in networks, telecommunications, server equipment and critical computer stations.
No, we have three models from this series in our offer. ORVALDI LT-2000 SINUS TOWER ranks second, if you need something in a smaller budget we recommend its predecessor. However, if you would like to opt for something with more power - check out its successor.
ORVALDI LT-2000 SINUS TOWER is equipped with: