EN
T2600G-28TS is a managed gigabit switch, equipped with 24 ports 10/100/1000 Mb/s, with automatic call negotiation and automatic crossover Auto-MDI/MDIX. Additionally, the device has 4 SFP 1000Mb/s ports and one Micro-USB port. The switch provides high performance, advanced QoS function support, protection strategies and network management functions in layer 2 and 2+. Additionally, it supports network traffic management functions and protects the network against threats. The IP-MAC-Port binding and access control lists (ACL, L2 to L4) protect the network against threats such as broadcast storm, ARP and DoS (Denial-of-Service) attacks. The Quality of Service (QoS, L2 to L4) function provides the ability to direct network traffic while ensuring smooth and faster data transmission.
Functions such as IP-MAC-Port binding, port protection, Storm Control and DHCP Snooping, effectively protect against ARP attacks, broadcast storm etc. Typical DoS attacks can be defined to be detected by the T2600G-28TS. This makes protection against them more effective than ever before. The use of access control lists (ACL, L2 to L4) prevents access to certain network resources; denial of packets can be set for specific source or destination MAC addresses, IP addresses, TCP/UDP ports and even VLAN identifiers. In addition, the switch uses 802.1X encryption in combination with RADIUS/Tacacs+ server functions to authenticate users wishing to access the network.
T2600G-28TS supports many ISP functions, such as OAM standard 802.3ah, DDM, sFlow, QinQ, L2PT PPPoE ID Insertion, IGMP authentication, etc. OAM function 802.3ah standard and Device Liaison Detection Protocol (DLDP) provides easier network surveillance and management and faster troubleshooting with an Ethernet network. In addition, the DDM (Digital Diagnostic Monitoring) function allows monitoring the status of SFP modules and configuring alarm, warning, temperature threshold, voltage threshold, polarity threshold, power threshold Tx and Rx. In addition, the switch supports many IPv6 features such as Dual IPv4/IPv6 Stack, MLD Snooping, IPv6 ACL, DHCPv6 Snooping, IPv6 interface, PMTU Discovery and IPv6 Neighbor Discovery. This ensures that the introduction of next-generation networks (NGNs) will not involve replacing the switch with a new one.
Switch T2600G-28TS uses layer 2 switch functions such as VLAN tagging, Port Mirroring, SFP/RSTP/MSTP, LACP and data flow functions. In addition, the switch supports advanced network security features such as feedback loop detection, cable diagnostics, and IGMP Snooping.
The T2600G-28TS switch is easy to use and manage. The device can be managed in various ways, e.g. through an intuitive graphical user interface in a web browser (GUI) or a command line interface (CLI). The transfer of packages can be protected with SSL or SSH encryption. Support for SNMP (1/2/3) and RMON protocols allows the switch to transmit relevant status information and capture unexpected events.
Features / filters | |
LAN standard | Gigabit Ethernet 10/100/1000 Mb/s |
Number of LAN ports | 24x [10/100/1000M (RJ45)] , 4x [1G (SFP)] , |
10G support | Yes |
AC input frequency | 50 - 60 |
Basic switching RJ-45 Ethernet ports quantity | 24 |
Basic switching RJ-45 Ethernet ports type | Gigabit Ethernet (10/100/1000) |
Cable types supported | Cat3,Cat4,Cat5,Cat5e |
Cables included | AC |
Console port | RJ-45 |
Depth | 220 |
DHCP features | DHCP server |
Fiber ethernet cabling technology | 1000Base-X |
Height | 44 |
Installed SFP modules quantity | 4 |
IP-MAC-Port binding | Yes |
IPv4 & IPv6 features | Dual stack IPv4/IPv6 |
Jumbo frames | 9216 |
Jumbo frames support | Yes |
Link aggregation | Yes |
MAC address table | 16000 |
Management | Yes |
MIB support | SNMP v1/v2c/v3,compatible with public MIBs and TP-LINK private MIBs, SYSLOG & Public MIBS |
Multicast Listener Discovery (MLD) snooping | Yes |
Multicast support | Yes |
Networking standards | IEEE 802.11d,IEEE 802.1p,IEEE 802.1s,IEEE 802.1w,IEEE 802.1x,IEEE 802.3ab,IEEE 802.3ad,IEEE 802.3i,IEEE 802.3u,IEEE 802.3x,IEEE 802.3z |
On/off switch | Yes |
Operating relative humidity (H-H) | 10 - 90 |
Operating temperature (T-T) | 0 - 40 |
Path MTU discovery | Yes |
Power (W) | Without PoE |
Power consumption (max) | 19.15 |
Power over Ethernet (PoE) | No |
Product colour | Black |
Quality of Service (QoS) support | Yes |
Rack mount kit | Yes |
Rack mounting | Yes |
Rate limiting | Yes |
Resource CD | Yes |
Rubber feet | Yes |
Security algorithms | 802.1x RADIUS |
SSH/SSL support | Yes |
Stackable | Yes |
Storage relative humidity (H-H) | 5 - 90 |
Storage temperature (T-T) | -40 - 70 |
Switch layer | L2 |
Switch type | Managed |
Switching capacity | 56 |
Switching layer | 2 |
Throughput | 41.67 |
Type of case | Desktop |
User guide | Yes |
Virtual LAN features | Private VLAN,Protocol-based VLAN |
VLAN support | Yes |
Web-based management | Yes |
Width | 440 |
Equipment features | |
Standards and protocols | IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3az, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1x, IEEE 802.1p |
Ports | 24 RJ45 ports 10/100/1000Mbps Automatic negotiation of connection speeds and automatic crossover (Auto-MDI/MDIX) 4 SFP ports 1000Mbps 1 RJ45 console port 1 Micro-USB console port |
Network cabling | 10BASE-T: Cat 3, 4 or 5 UTP cable (up to 100m) 100BASE-TX/1000Base-T: Cat 5, 5e or higher UTP cable up to 100m 1000BASE-X: MMF, SMF |
Fanless | Yes |
Physical security | Yes |
Power supply | 100~240VAC, 50/60Hz |
Dimensions (S x G x W) | 440*220*44 mm (17.32*8.7*1.73 inches) |
Installation | For mounting in a cabinet |
Max. energy consumption | 15.33W (220V/50Hz) |
Amount of heat generated | 52.30 BTU/h |
Performance | |
Switching capacity | 56Gb/s |
Packet forwarding rate | 41.67Mp/s |
MAC address table | 16k |
Jumbo frames | 9216 Bytes |
Software functions | |
Quality of Service function | Prioritization of CoS/DSCP traffic based on the IEEE 802.1p standard 8 queues Setting the queue of priorities: SP, WRR, SP+WRR Limitation of transmission depending on port, data flow Voice VLAN |
L2 and L2+ functions | Static routing DHCP Relay IGMP Snooping V1/V2/V3 LACP support (according to 802.3ad standard (up to 8 groups, maximum 8 ports per group) Spanning Tree STP/RSTP/MSTP BPDU filtering/protection TC/Root Protect Feedback loop detection Data flow control (802.3x) L2PT |
VLANs | IEEE802.1Q support, up to 4000 VLAN and 4000 VLAN identifiers 802.1Q/MAC/Protocol/Private VLAN GARP/GVRP |
Access control lists | Packet filtering based on source and destination MAC addresses L2~L4 IP address, TCP/UDP ports, 802.1p, DSCP, protocol and VLAN ID Limited in time |
Transmission security | IP-MAC-Port-VID binding AAA Authentication based on IEEE 802.1X standard, Radius Protection against DoS attacks Dynamic protection against ARP (DAI) attacks SSH v1/v2 SSL v2/v3/TLSv1 Port security Broadcast/Multicast/Unknown-unicast Storm Control |
IPv6 | Dual IPv4/IPv6 stack MLD Snooping IPv6 ND MTU detection ICMPv6 TCPv6/UDPv6 IPv6 access control list DHCPv6 Snooping IPv6 interface |
IPv6 applications | DHCPv6 customer Ping6 Tracert6 Telnet(v6) IPv6 SNMP IPv6 SSH IPv6 SSL Http/Https IPv6 TFTP IPv6 access control list IPv6 interface Routing IPv6 DHCPv6 relay DHCPv6 Snooping |
Management | GUI browser interface, CLI command line interface SNMP v1/v2c/v3, compatible with TP-LINK public and private MIB libraries RMON (groups 1, 2, 3, 9) sFlow PPPoE Circuit ID DHCP Relay DHCP server Customer DHCP/BOOTP, DHCP Snooping, DHCP Option82 Dual Image CPU monitoring Port Mirroring SNTP time synchronization Firmware update: via TFTP protocol and web browser Diagnostics: VCT test System logos, MIB public libraries Password recovery |
Other | |
Certificates | CE, FCC, RoHS |
Package contents | The switch; Power cable; Quick Installation Guide; CD; Mounting elements (for mounting in racks); Rubber coasters |
System requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8, MAC® OS, NetWare®, UNIX® or Linux. |
Working environment | Operating temperature: 0℃~40℃ (32℉~104℉); Storage temperature: -40℃~70℃ (-40℉~158℉) Operating humidity: 10%~90%, non-condensing Storage humidity: 5%~90%, non-condensing |